Evans, S. (2003). Improving nursing care of infants and children ventilated with uncuffed endotracheal tubes. Pediatric Intensive Care Nursing, 4(2), 7.
Abstract: The author draws on her experience as the 'Paediatric Link Nurse' in an Intensive Care Unit (ICU) within a metropolitan area in New Zealand to examine the proposed changes to ventilation practice. Currently, due to ventilator availability and medical and nursing practice, the usual mode of mechanical ventilation is volume-limited with pressure breath triggering. The author suggests this mode can compromise effective ventilation of paediatric patients, due to air leaks around the uncuffed endotracheal tubes of infants and small children. This air leak makes a guaranteed tidal volume almost impossible and can cause ventilator breath stacking and volutrauma. This can impact on the patient's comfort, sedation requirements and airway security, and affects how these patients are nursed. Thus the ventilation of these paediatric patients by the current volume-limiting mode may be not always be optimal for the infant/child. A new ventilator will be available to the unit, with a pressure-controlled, flow breath-triggering mode available. The author critiques the possibility of using this mode of ventilation, suggesting how this will impact on nursing practice in ICU, and of the education and knowledge that will be required. She suggests this change to ventilation practice may improve comfort and safety for the intubated child/infant, through the delivery of an optimal mode of ventilation.
|
|
|
Fairhall, M. (2008). An observational study of Peripherally Inserted Central Cather(PICC)-related complications amongst oncology patients. Ph.D. thesis, , .
Abstract: This thesis reports on a retrospective observational study that examined the complication rate of peripherally inserted central catheters (PICCs) within a regional cancer centre. PICCs are increasingly used for delivery of chemotherapy and other intravenous therapies in oncology patients. A literature review revealed that almost all published research on PICC complications reported on silicone (Groshong(TM)) catheter use, rather than the polyurethane (Arrow(TM)) PICCs used at Christchurch Hospital. Also, much literature referred to PICCs being inserted by non-nurses, whereas the Christchurch service uses specially-trained nurses to insert them. The purpose of the study was to identify the nature, incidence and rates of polyurethane (Arrow(TM)) PICC complications in an adult oncology cohort. Ethics Committee approval was gained to retrospectively follow all PICCs inserted in adult oncology patients at Christchurch Hospital over a 13-month period from 1st March 2006 until 31st March 2007. Data collected were analysed utilising the statistical computer package SPSS. One hundred and sixty-four PICCs were inserted into 156 individual oncology patients over this period. The median dwell time was 68 days for a total of 14,276 catheter-days. Complications occurred in 25 (15%) out of 164 PICC lines, in 22 (15%) of the 156 patients for an overall complication rate of 1.75 per 1000 catheter-days. However, only 16 of the 25 PICCs with complications required early removal (9.75% of the cohort) for a favourably low serious complication rate of 1.12 per 1000 catheter-days. The three commonest complications were infection at 4.3% (7/164) or 0.49 infection complications/1000 PICC-days, PICC migration at 3% (5/164) or 0.35/1000 catheter days, and thrombosis at 2.4% (4/164) or 0.28/1000 catheter days. The median time to complication was 41 days. Those with complications were more likely to have a gastro-intestinal or an ovarian cancer diagnosis, and less likely to have colorectal cancer. These findings provide support for the safe and effective use of polyurethane (Arrow(TM)) PICCs for venous access within the adult oncology context. Furthermore, it suggests that cost effective nurse-led (Arrow(TM)) PICC insertions can contribute to a low complication rate.
|
|
|
Ho, T., & Mok, J. (2003). Condensate clearance from CPAP circuit: An examination of two methods of draining condensate from the inspiratory tubing. Journal of Neonatal Nursing, 9(4), 117–120.
Abstract: Clinical studies on adult ventilated patients demonstrate that bacterial contamination of the condensate occurs in ventilator circuits. The purpose of this research is to find out if this is also true of the condensate in the Continuous Positive Airway Pressure (CPAP) circuit. It aims to determine whether there is bacterial contamination in the humidifier reservoir of the CPAP system when the condensate is drained back into the humidifier reservoir without disconnecting the circuit, or when the inspiratory tubing is disconnected to drain out the condensate.
|
|